KBID: KB00008646

Topic:

WebUI

Ephesoft Versions:

v3.1.x or higher

Issue:

Test Classification Functionality in the UI is failing.
User is getting the following error in the UI:

 

Root Cause:

There is a dependency on the Page Process script plugin being present in the workflows.
This can happen when the exported BC does not have the Script files in it so when you import the batch class, all the scripts are missing causing the classification test in the UI to fail because the script plugin was not able to execute properly.

Solution: 

You need to do the following:

1. Add the page process script plugin to the workflows
2. Make sure the scripts folder has all the java files so that no other scripting plugin fails.

 

 

< Back|KB Main Page

Was this article helpful to you?

wikiadmin

Comments are closed.